Peltier Cooling System

NEW

Sample Cooling Down to -10°C

Related product: Acquire™

Description

Flownamics introduces the Peltier+™ Sample Cooling System — our most compact and fully self-contained cooling device. Designed for efficiency and precision, this thermoelectric system uses advanced Peltier cooling technology to keep racks of samples at consistent temperatures without the need for external chillers or coolant lines. By combining the rapid response of Peltier elements with the stable performance typically associated with liquid chillers, the Peltier+ delivers the best of both worlds—dry, maintenance-free operation with highly reliable cooling.

The Peltier+ features two independent cooling zones, allowing different temperature setpoints for each side. This flexibility enables simultaneous cooling of two distinct sample types or workflows. Operation is simple: just power on the unit and set your desired temperatures using the dual digital controllers located on the front panel. The current operating range is -2° to 20° Celsius, and the front display provides real-time coolant temperature monitoring for added assurance.

No assembly or training is required, making the Peltier+ a true plug-and-play solution. Integrated condensation management helps minimize moisture buildup on work surfaces, while built-in safety functionality automatically shuts down the system in the event of a coolant issue, protecting both users and equipment. With no external pumps or tubing to manage, ongoing maintenance is minimal, making it ideal for busy lab environments.

This system supports a wide range of rack and vial formats, from 2 mL HPLC vials to 50 mL conical tubes. It is optimized for use with Flownamics racks, which are designed to ensure proper thermal contact and alignment, but it can also be used with other rack types. Custom racks and configurations are available upon request to meet your specific application needs. The Peltier+ also accommodates microtiter plates, with space for two plates per cooling surface.

Compact, quiet, and easy to use, the Peltier+ is an ideal solution for laboratories seeking efficient, reliable sample cooling without the complexity of traditional liquid-based systems. Future-ready features like OPC communication (coming soon) will enable integration into digital lab environments for remote control and monitoring. Contact Flownamics for more information about the Peltier+, custom cooling solutions, or OEM integration options.

Product Specifications

Dimensions

13.25” W x 20.375” D x 5.5” H (33.7 cm W x 51.7 cm D x 14 cm H)

Weight

15 lbs (6.8 KG)

Temperature Range

0° to 20° C

2 Temperature Zones

2 Temperature Zones

Holds 2 racks

Holds 2 racks

Rack Sizes

Microtiter Plate Rack (Holds 2 plates)
60 – 2ml HPLC vials Rack
60 – 5ml vials Rack
30 – 15 ml conical tubes Rack
14 – 50 ml conical tubes Rack
Custom Racks

OPC Communication

Option Coming Soon

Features & Benefits

  • Plug & Play Design
    Just power it on, set your desired temperatures, and begin cooling—no setup or assembly required.
  • Dual Independent Temperature Zones
    Two separately controlled cooling plates allow simultaneous sample storage at different temperatures, ideal for multi-process workflows.
  • Simple, Intuitive Operation
    No user training required—precise temperature control through front-facing digital interfaces.
  • Advanced Cooling Without the Liquid Chiller
    Combines the precision of Peltier technology with the thermal stability of liquid chillers—without the added bulk, fluid maintenance, or plumbing.
  • Low-Maintenance Operation
    No external chiller, coolant, or pump system to manage—just clean, efficient thermoelectric cooling.
  • Cooling Down to -2°C
    Maintains temperatures as low as -2°C to ensure sample stability, minimize degradation, and support chilled reagent workflows.
  • Compact, Fully Self-Contained Unit
    Small footprint fits easily on lab benches or inside instrumentation suites—no external components required.
  • Built-In Condensation Management
    Helps reduce surface moisture buildup during low-temperature operation, keeping your workspace clean and dry.
  • Integrated Safety Functionality
    Automatic system shutdown in the event of coolant flow issues to reduce risk of equipment damage or user injury.
  • Flexible, Modular Platform
    Designed for use with a wide range of Flownamics racks and vial formats; custom configurations available to suit your workflow.
  • OEM and Custom Integration Ready
    Tailored versions and system-level integration available for specialized lab environments or instrument manufacturers.
  • OPC Communication Option Coming Soon
    Future-ready for digital integration—remote control and monitoring through OPC protocol will be available in upcoming versions.

Literature

Peltier+ Brochure

Quality Makes the Difference

Flownamics® has been creating innovative, high quality solutions for the biotechnology and bioprocess industry for over 27 years.

Our products provide our users with the tools that they need to improve their processes through automation. This results in higher quality data, more time, and a better work/life balance by requiring less off shift and weekend workloads. Contact Flownamics® to see how our products can make a difference for your process.

Read Our Publications

Our products have been featured in a variety of industry publications. Please visit our Publications page to learn more.